500W Series
190-01226-03 Rev. 5
Instructions for Continued Airworthiness Bell 206B
Page 18 of 23
Alert Text
Possible Cause
Solution
TAWS has failed
The 500W Series unit has detected a
failure in its TAWS system.
Ensure that terrain database
is inserted in right most card
slot.
Reload the terrain database.
Contact Garmin technical
support.
TAWS inhibit key stuck
The external TAWS inhibit key is
stuck.
Verify that the wiring is not
shorted to ground.
Contact Garmin technical
support.
TAWS mute caution
key is stuck
The external HTAWS aural
suppression input is stuck
Try pressing the TAWS mute
key again to cycle its
operation. If problem persists
contact Garmin technical
support.
TAWS reduced
protection key is stuck
The external TAWS reduced
protection key is stuck
Try pressing the TAWS
reduced protection key to
cycle its operation. If the
problem persists contact
Garmin technical support.
TERRAIN configuration
conflict
The current Terrain configuration is
not supported by the hardware.
Reconfigure the unit.
TERRAIN configuration
has changed
The unit’s terrain settings have
changed since it was last turned on
in normal mode.
Reconfigure TERRAIN
settings
Contact Garmin technical
support
Terrain database
integrity error
The 500W Series unit has detected a
problem with a database on the
Terrain data card.
Reloading the information
onto the card.
Replace the card.
TERRAIN has failed
The unit has detected a failure in the
terrain system.
Ensure that Terrain database
is inserted in the right most
card slot.
Reload the TERRAIN
database.
Contact Garmin technical
support.
Traffic device has failed
The 500W Series unit cannot
communicate with the traffic system
and/or the traffic system is reporting a
system failure.
Check for proper configuration
Check for correct wiring
Refer to the Traffic system
installation manual.
Traffic device needs
service
The traffic device is reporting a system
failure.
Refer to the Traffic system
installation manual.
User card format
unknown
A data card has been inserted, but the
format of the card is not recognized.
Reload the information onto
the card. If that does not
solve the problem replace the
card.
Summary of Contents for 500W Series
Page 23: ......