190-01773-00 Rev. A
AOA System Owner’s Manual
3
AOA System
A failure is indicated by alternating flashing red chevrons and a “Beep - Beep”
audible alert.
GI 260 Self Test (Fail)
Alternating
flashing red
chevrons
Beep - Beep
MUTE
S
tart
-U
p
The system is muted by default upon start-up. The system remains muted until 15
seconds has elapsed since start-up and the Angle of Attack reaches the upper yellow
chevron. The first slow audible “Beep-Beep” alert is heard when the upper yellow
chevron annunciator illuminates.
N
ormal
o
peratioN
Press the
MUTE
(SET) button to mute the GI 260 audible alert. When muted
manually during normal operation, the audio alert is muted for at least 15 seconds
and remains muted until the upper green bar illuminates for at least five seconds.