Specifications
34
Apollo GX50/60/65 Installation Manual
E
NVIRONMENTAL
The Apollo GX50 and GX60/65 units are designed and tested to meet appropriate categories
of RTCA/DO-160C. The Environmental Qualification Form is included in Appendix C.
Operating temperature...............................-20
°
C to +55
°
C
Storage temperature ..................................-55
°
C to +85
°
C
Temperature variation ...............................2
°
C per minute
Humidity ...................................................95% at 50
°
C for 6 hours (2 day cycle)
Maximum altitude.....................................55,000 feet
Cooling......................................................Not required
GPS
R
ECEIVER
P
ERFORMANCE
Number of channels ..................................8
Frequency..................................................1575.42 MHz L1, C/A code
Sensitivity (acquisition) ............................-135 dBm
Sensitivity (drop lock)...............................-142 dBm
Dynamic range ..........................................> 20 dB
Figure 15 Unit Dimensions
Summary of Contents for Apollo GX50
Page 4: ...NOTES...
Page 8: ...Table of Contents iv Apollo GX50 60 65 Installation Manual NOTES...
Page 30: ...Installation 22 Apollo GX50 60 65 Installation Manual Figure 12 RS 232 Serial Connections...
Page 31: ...Installation Apollo GX50 60 65 Installation Manual 23 Figure 13 GX60 65 Comm Wiring Diagram...
Page 40: ...Installation 32 Apollo GX50 60 65 Installation Manual NOTES...
Page 50: ...Limitations 42 Apollo GX50 60 65 Installation Manual NOTES...
Page 54: ...Periodic Maintenance 46 Apollo GX50 60 65 Installation Manual NOTES...
Page 82: ...Serial Interface Specifications 74 Apollo GX50 60 65 Installation Manual NOTES...
Page 84: ...Full Stack Drawing 76 Apollo GX50 60 65 Installation Manual...
Page 85: ......
Page 86: ......