Serial Interface Specifications
56
Apollo GX50/60/65 Installation Manual
M
OVING
M
AP
O
UTPUT
The format of the moving map data output is as follows. Definitions of the output data is
included in Table 6 and Table 7. A sample output message is included in Figure 17.
Baud rate: ..........................................9600
Data bits: ...........................................8
Stop bits: ...........................................1
Parity: ................................................none
Output rate: .......................................approx. 1 seconds
Message length: ................................variable, approx. 83 to 750 characters
The serial output messages are in the following format.
<STX><id><data><it><id><data><it>...<id><data><it><ETX>
<STX> ..............................................ASCII “start of text” character (1 byte, 02h)
<id> ...................................................item designator (1 byte, from following table)
<data> ...............................................item data (format listed in following table)
<it> ....................................................item terminator (1 byte, 0Dh)
<ETX> ..............................................ASCII “end of text” character (1 byte, 03h)
Summary of Contents for APOLLO GX60
Page 4: ...NOTES ...
Page 8: ...Table of Contents iv Apollo GX50 60 65 Installation Manual NOTES ...
Page 30: ...Installation 22 Apollo GX50 60 65 Installation Manual Figure 12 RS 232 Serial Connections ...
Page 31: ...Installation Apollo GX50 60 65 Installation Manual 23 Figure 13 GX60 65 Comm Wiring Diagram ...
Page 40: ...Installation 32 Apollo GX50 60 65 Installation Manual NOTES ...
Page 50: ...Limitations 42 Apollo GX50 60 65 Installation Manual NOTES ...
Page 54: ...Periodic Maintenance 46 Apollo GX50 60 65 Installation Manual NOTES ...
Page 82: ...Serial Interface Specifications 74 Apollo GX50 60 65 Installation Manual NOTES ...
Page 84: ...Full Stack Drawing 76 Apollo GX50 60 65 Installation Manual ...
Page 85: ......
Page 86: ......