G1000 / GFC 700 System Maintenance Manual - 300/B300 Series King Air
Page 5-61
190-00716-01
Revision 1
5.11.5
GIA Cooling Alerts
Failure Message
Cause
Solution
GIA1 COOLING – GIA1
temperature too low.
GIA1 operating temperature is too
low.
•
Allow unit to warm up.
GIA2 COOLING – GIA2
temperature too low.
GIA2 operating temperature is too
low.
•
Allow unit to warm up.
GIA1 COOLING – GIA1 over
temperature.
GIA1 has exceeded its operating
temperature range.
•
Check fan, wiring and air tubing for
proper operation (if applicable).
•
Replace cooling fan if unable to
determine if operating correctly.
•
Replace
GIA1.
•
If problem persists contact Garmin
Aviation Product Support for
assistance.
GIA2 COOLING – GIA2 over
temperature.
GIA2 has exceeded its operating
temperature range.
•
Check fan, wiring and air tubing for
proper operation (if applicable).
•
Replace cooling fan if unable to
determine if operating correctly.
•
Replace
GIA2.
•
If problem persists contact Garmin
Aviation Product Support for
assistance.