G1000 / GFC 700 System Maintenance Manual - 300/B300 Series King Air
Page 5-71
190-00716-01
Revision 1
3.
This page is protected and requires a keystroke password to perform this test. Press the following
softkeys in sequence: (as counted from left to right on lower bezel of MFD)
•
softkey 9
•
softkey 10
•
softkey 11
•
softkey 12
4.
Select MAG INTERFERENCE TEST and press the PFD1 ENT key.
5.
Follow the checklist items displayed on the PFD1, and press the ENT key as each one is
completed or confirmed.
NOTE
The 3
rd
item on the checklist instructs the operator to “prepare a detailed test sequence
with precise start and stop times for exercising all electronic devices”. The list of
relevant electronic devices are given in Table 5-5. Begin test with flaps retracted, flight
controls in a neutral position, all lights selected OFF.
Elapsed Time since Start of Test
(min:secs)
Action
0:00 Test
begins
0:05
Tail Flood lights on
0:10
Tail Flood lights off
0:20 Navigation
lights
on
0:30 Navigation
lights
off
0:40 Landing
lights
on
0:50 Landing
lights
off
1:00 Taxi
lights
on
1:20 Taxi
lights
off
1:40 Strobes
on
1:50 Strobes
off
2:00
Recognition lights on
2:10
Recognition lights off
2:20 Beacon
on
2:30 Beacon
off
2:40
Rudder full left
2:50
Rudder full right
3:00
Elevator full nose UP
3:10
Elevator full nose DN
3:15 End
of
test