Page 3-8
G1000 / GFC 700 System Maintenance Manual - 300/B300 Series King Air
Revision 1
190-00716-01
Data can be manually copied from one column to the other (and consequently from PFD memory to the
LRU memory and vice-versa) by using the following two softkeys, when available:
•
SET>ACTV (read ‘Set to Active’) softkey: Allows the installer to send the information in the
SET column (data stored in the master config module) to the ACTV column (data used by LRU).
•
ACTV>SET (read ‘Active to Set’) softkey: Causes the LRUs current settings to be copied to the
master configuration module as SET items.
CAUTION:
The ACTV>SET softkey must be used with caution! If an improperly configured
unit is installed, this softkey causes the wrong configuration to replace the correct
aircraft configuration.
In the first example shown in Figure 3-10, the SET columns do not match the ACTIVE
columns. The inequality between SET and ACTIVE indicates a configuration mismatch.
By pressing the SET>ACTV softkey, this copies the SET column to the LRU unit’s
configuration memory. The settings then become the ACTIVE settings for the LRU
being configured.
=
=
Master Configuration Module
LRU Memory
Master Configuration Module
LRU Memory
Master Configuration Module
LRU Memory
=
Master Configuration Module
LRU Memory
=
Configuration Mismatch
SET>ACTV Softkey
Configuration Correct
Figure 3-10, SET>ACTV Diagram