____________________________________________________________________
Page 5-96
G1000 System Maintenance Manual
Rev. A
190-00903-00
5.1.8.14
RS-232/ARINC 429 Configuration Page (GIA 63/63W)
Figure 5-19. RS-232/ARINC 429 Configuration Page
Main ARINC 429 and RS-232 communications channels for GIA 1 and GIA 2 are displayed on
this page. All settings are pre-established for a particular installation and are loaded from the
G1000 Loader Card and should not be changed. The ‘GIA 1’ and ‘GIA 2’ configuration files
contain the settings shown on this page.
Windows:
a.
SELECT UNIT
―
displays the currently selected GIA 63/GIA 63W unit.
b.
RS-232
―
displays active RS-232 configuration settings for currently selected GIA.
c.
ARINC 429
―
displays active ARINC 429 configuration settings for currently selected GIA.
Softkeys:
The following softkeys are displayed on this page:
a.
SET>ACTV
―
See configuration section for description.
b.
ACTV>SET
―
See configuration section for description.
c.
CLR NV
―
clears all ‘Active’ settings from memory from the selected GIA 63/GIA 63W and
restores default settings. The GIA and optional equipment configuration files need to be
reloaded if the memory is cleared.