__________________________________________________________________________
G1000 System Maintenance Manual
Page 6-11
190-00903-00
Rev.
A
To install:
1.
Crimp pins (item 2) onto each of the thermocouples wires (item 1). Ensure that pre-stripped
wire length is 1/8" prior to crimping.
2.
Insert newly crimped pins and wires into the appropriate connector housing location (item 6).
3.
Place thermocouple body (item 1) onto the backshell boss (item 5). Place the thermocouple
as shown in Figure 6-3 (the wires exit towards the bottom of the backshell).
4.
Fasten thermocouple tightly to backshell using the provided screw (item 6).
5.
Fasten cover (item 6) to backshell using the provided screw (item 7).