____________________________________________________________________
Page A-18
G1000 System Maintenance Manual
Rev. A
190-00903-00
A.11 P701 (GEA 71)
View of J701 connector looking at unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
Pin Pin
Name
I/O
1
CONFIG MODULE GROUND
--
2 DIGITAL
IN*
1
In
3 DIGITAL
IN*
2
In
4 SIGNAL
GROUND
--
5 RS-485
1
A
I/O
6 RS-485
1
B
I/O
7 RS-485
2
A
I/O
8 RS-485
2
B
I/O
9
GEA SYSTEM ID PROGRAM* 1
In
10
GEA SYSTEM ID PROGRAM* 2
In
11
TRANSDUCER POWER OUT LO (GROUND)
--
12
TRANSDUCER POWER OUT LO (GROUND)
--
13
TRANSDUCER POWER OUT LO (GROUND)
--
14
+10 VDC TRANSDUCER POWER OUT
Out
15
+5 VDC TRANSDUCER POWER OUT
Out
16
+12 VDC TRANSDUCER POWER OUT
Out
17
ENGINE TEMP ANALOG IN 6 HI
In
18
ENGINE TEMP ANALOG IN 6 LO
In
19 SIGNAL
GROUND
--
20 POWER
GROUND
--
21
CONFIG MODULE POWER OUT
Out
22
ANALOG IN 1 HI
In
23
ANALOG IN 1 LO
In
24
ANALOG IN 2 HI
In
25
ANALOG IN 2 LO
In
26
ENGINE TEMP ANALOG IN 1 HI
In
27
ENGINE TEMP ANALOG IN 1 LO
In
28
ENGINE TEMP ANALOG IN 2 HI
In
29
ENGINE TEMP ANALOG IN 2 LO
In
30
ENGINE TEMP ANALOG IN 3 HI
In
31
ENGINE TEMP ANALOG IN 3 LO
In
32 SIGNAL
GROUND
--
33
ENGINE TEMP ANALOG IN 4 HI
In
34
ENGINE TEMP ANALOG IN 4 LO
In
35
AIRCRAFT POWER 1
In
36
ENGINE TEMP ANALOG IN 5 HI
In
37
AIRCRAFT POWER 2
In
38
ENGINE TEMP ANALOG IN 5 LO
In