G1000 System Maintenance Manual
Page 4-1
190-00903-00
Rev.
A
SECTION 4
CONFIGURATION MODE
This section describes the configuration mode of operation. This section presumes basic
familiarity with the operation of the G1000.
4.1 INTRODUCTION
Configuring, calibrating, and troubleshooting the G1000 is performed in the configuration mode.
To enter configuration mode:
1.
Press and hold the ENT key on the PFD while applying power. Release the ENT key after
‘INITIALIZING SYSTEM’ is displayed in the upper left corner of the PFD.
2.
Repeat step 1 for PFD 2 (if installed). The System Status Page (Figure 4-1) is displayed on
the MFD and the PFD.
3.
Press the 12
th
softkey on GDU 1xxx that does not have an ENT key to enter Config Mode.
Figure 4-1. System Status Page (Configuration Mode)