G1000 System Maintenance Manual
Page 5-41
190-00903-00
Rev.
A
MFD DB ERR – MFD ChartView
database error.
The MFD has encountered
an error in the ChartView
database.
MFD DB ERR – MFD Terminal
Procs database error exists.
The MFD has encountered
an error in the Terminal
Procedures database.
•
Confirm supplemental data card
is inserted fully in the bottom
slot of the display.
•
Move the datacard to the top
slot of the display.
−
If the error clears, the
problem is with the bottom
slot. Insert and remove a
SD card multiple times to
clean the contacts. If the
card still does not work in
the bottom slot, leave the
card in the top slot or
replace the display.
•
Reload ChartView from
Jeppesen’s loader program.
•
Replace supplemental data
card. You may need to replace
all datacards as a set to keep
the database cycles the same
and prevent database
mismatch errors.
•
Replace
MFD.
DB MISMATCH – Aviation
database version mismatch.
Xtalk is off.
The G1000 has found the
Jeppesen aviation database
in the PFDs and MFD do not
match.
Load the same cycle of aviation
database to all displays.
DB MISMATCH – Aviation
database type mismatch.
The G1000 has found the
Jeppesen aviation database
types do not match.
Load same type aviation database
to all displays.