5.1.6.14
GMA 1347D Advisory Messages
Advisory Message
Possible Cause
Recommended Actions
MANIFEST – GMA1 software
mismatch. Communication
Halted.
The system has detected an
incorrect software version
loaded in GMA 1347D #1.
Load correct software version.
MANIFEST – GMA2 software
mismatch. Communication
Halted.
The system has detected an
incorrect software version
loaded in GMA 1347D #2.
Load correct software version.
GMA1 SERVICE – GMA1 needs
service. Return unit for repair.
The G1000 has determined
GMA 1347D #1 needs
service.
Replace GMA 1347D #1.
GMA2 SERVICE – GMA2 needs
service. Return unit for repair.
The G1000 has determined
GMA 1347D #2 needs
service.
Replace GMA 1347D #2.
GMA1 FAIL – GMA 1 is
inoperative.
The G1000 has detected a
failure in GMA 1347D #1.
•
Ensure GMA 1347D #1, both
GIAs and all GDUs are
receiving power.
•
Troubleshoot for a failed
datapath using Section 5.1.5.
•
Replace GMA 1347D #1.
GMA2 FAIL – GMA 2 is
inoperative.
The G1000 has detected a
failure in GMA 1347D #2.
•
Ensure 1347D #2, both GIAs
and all GDUs are receiving
power.
•
Troubleshoot for a failed
datapath using Section 5.1.5.
•
Replace GMA 1347D #2.