______________________________________________________________________________
____________________________________________________________________________
Page 4-18
LMM for the Kodiak 100
190-02102-00 Rev.4
HDG FAULT
AHRS1 magnetometer fault has
occurred.
• GMU 44/44B
HW MISMATCH
GIA HW mismatch. Only one GIA
is SBAS capable.
• GIA 64W
LOI
GPS information loss of integrity
has been detected.
• GIA 64W
MFD1 BKLT CAL INV
MFD1 backlight calibration lost.
• GDU 1050
MFD1 CONFIG
MFD1 configuration error.
• GDU 1050
• Master Config
Module
MFD1 COOLING
MFD1 has poor cooling. Reducing
power usage.
• GDU 1050
MFD1 KEYSTK
A key is stuck on the MFD1 bezel.
• GDU 1050
MFD1 MANIFEST
MFD1 software mismatch.
• GDU 1050
MFD1 SERVICE
A fault has been detected in
MFD1.
• GDU 1050
MFD1 VOLTAGE
MFD1 has low voltage.
• GDU 1050
NAV 1 INOP - CAL
Check NAV Calibration.
• GIA 64W
NAV 1 INOP - CONFIG
A NAV software or configuration
fault.
• GIA 64W
NAV 1 INOP - INTRL
A NAV internal fault.
• GIA 64W
NAV 1 INOP - SERL
A NAV serial communication fault.
• GIA 64W
NAV 1 INOP - SYNTH
NAV synthesizer lock fault.
• GIA 64W
NAV1 MANIFEST
NAV1 software mismatch.
• GIA 64W
NAV1 RMT XFR
The NAV1 remote transfer key line
is stuck in the enabled state.
• GIA 64W
NAV1 SERVICE
A fault has been detected in the
NAV subsystem of GIA1.
• GIA 64W
NAV 2 INOP - CAL
Check NAV Calibration.
• GIA 64W
Table 4-1. Troubleshooting System Messages (Continued)
System Message
Description
Possibly Faulty
LRU / Subsystem
Uncontrolled if Printed