______________________________________________________________________________
____________________________________________________________________________
LMM for the Kodiak 100
Page 4-39
190-02102-00 Rev.4
COM1 INOP - CRNT
The COM subsystem of
GIA1 is inoperative due
to a current fault.
• Check the aircraft supply
voltage.
• Check input voltage to the
GIA.
• Check for loose
connections, bent pins, or
shorts.
• Cycle power to the GIA.
• Retrieve log from CMC fault
Folder.
• If the fault persists, replace
the GIA.
COM1 INOP - INTRL
The COM subsystem of
GIA1 is inoperative due
to an internal fault.
• Cycle power to the GIA.
• Retrieve the log from CMC
fault folder.
• If the fault persists, replace
the GIA.
COM1 MANIFEST
COM1 has incorrect
software installed and
communication is halted.
• Load the correct software.
COM1 PTT
The COM1 push-to-talk
(PTT) key line is stuck in
the enabled state.
• Press the PTT switch to
cycle its operation.
• Check the PTT switch and
wiring.
• Check the GIA to GMA
interconnect.
• If the fault persists, replace
the GIA.
• If the fault persists, replace
the GMA.
Table 4-5. GIA 64W System Messages (Continued)