COM1 TEMP
The system has detected
an over temperature
condition in COM1. The
transmitter is operating at
reduced power.
• Check the fan, wiring, and
air tubing for proper
ventilation (if applicable).
• Replace the cooling fan if
not able to find if it is
operating properly.
• If the problem persists,
replace the GIA.
COM2 CONFIG
COM2 configuration error. • Reload configuration to the
GIA.
• If the fault persists, check
the configuration module
wiring for faults and replace
if necessary.
• If the fault persists, replace
the master configuration
module.
• If the fault persists, replace
the GIA.
COM2 INOP - CAL
The COM subsystem of
GIA1 is inoperative due
to loss of factory
calibration.
• Load the correct software.
• Cycle power to the GIA.
• If the problem persists,
replace the GIA.
COM2 INOP - CRNT
The COM subsystem of
GIA1 is inoperative due
to a current fault.
• Check the aircraft supply
voltage.
• Check input voltage to the
GIA.
• Check for loose
connections, bent pins, or
shorts.
• Cycle power to the GIA.
• Retrieve log from CMC fault
Folder.
• If the fault persists, replace
the GIA.
COM 2 INOP - INTRL
The COM subsystem of
GIA1 is inoperative due
to an internal fault.
• Cycle power to the GIA.
• Retrieve the log from CMC
fault folder.
• If the fault persists, replace
the GIA.
Table 4-5. GIA 64W System Messages (Continued)
System Message
Cause
Recommended Actions