______________________________________________________________________________
____________________________________________________________________________
Page 4-48
LMM for the Kodiak 100
190-02102-00 Rev.4
NAV1 INOP - INTRL
NAV internal fault.
• Cycle power to the GIA.
• Replace the GIA.
NAV1 INOP - SERL
An internal NAV serial
communication fault.
• Check data bus wiring.
• Check status of the other
LRU.
• Retrieve log from CMC fault
folder.
• Replace the GIA.
NAV1 INOP - SYNTH
NAV synthesizer lock
fault.
• Cycle power to the unit.
• Perform a radio check.
• Retrieve log from CMC fault
folder.
• Replace the GIA.
NAV1 MANIFEST
NAV1 software mismatch.
• Load the correct software.
NAV1 RMT XFR
The NAV1 remote transfer
key line is stuck in the
enabled state.
• Press the NAV1 remote
transfer switch to cycle its
operation.
• Check the NAV1 remote
transfer switch and wiring.
• If the fault continues,
replace the GIA.
NAV1 SERVICE
A fault has been detected
in the NAV subsystem of
GIA1.
• Replace the GIA.
NAV2 INOP - CAL
Factory NAV calibration
lost or corrupted.
• Replace the GIA.
NAV2 INOP - CONFIG
NAV internal fault.
• Cycle power to the GIA.
• Retrieve log from CMC fault
folder.
• Replace the GIA.
NAV2 INOP - INTRL
NAV internal fault.
• Cycle power to the GIA.
• Replace the GIA.
Table 4-5. GIA 64W System Messages (Continued)
System Message
Cause
Recommended Actions