______________________________________________________________________________
____________________________________________________________________________
LMM for the Kodiak 100
Page 4-65
190-02102-00 Rev.4
Configuration Fault
Both internal and
external configuration
checks failed
• Verify the configuration
through the GTS Install
Tool.
• Verify wiring to the
configuration module and
replace if necessary.
FPGA Fault
ROM Fault
Execution Fault
Electrical Fault
Whisper Shout Fault
• .
Internal Fault
• Replace the unit.
Transmit Power Fault
• .
Internal voltages are out
of tolerance
• Check power connections
to the GPA 65 to verify that
they are not connected to
ground or each other.
Ensure that power and
ground connections to the
GPA 65 are connected in
their proper place. Verify
input voltage and if it
continues return to Garmin
for service.
1030 MHz Fault
1090 MHz Fault
• Internal Fault.
• Replace the unit.
PA/LNA Fault
Receiver Fault
Transmitter Fault
• Antenna connections
or internal fault.
• Ensure all antenna
connections are correct
otherwise replace the unit.
Baro Altitude Fault
• Baro Altimeter is not
powered on or
improper wiring.
• Improper configuration
settings.
• Verify the baro altimeter
has power and is properly
wired.
• Verify the configuration is
set correctly using the GTS
Install Tool.
Temperature Fault
• Fan is not operating,
Poor ventilation at the
mounting location.
• Verify the fan is running
and the unit is getting
adequate ventilation.
Table 4-8. GTS Troubleshooting (Continued)
Problem
Cause
Solution
Uncontrolled if Printed
Summary of Contents for Cessna Caravan G1000
Page 2: ...BLANK PAGE Uncontrolled if Printed...
Page 288: ...Uncontrolled if Printed...