______________________________________________________________________________
____________________________________________________________________________
LMM for the Kodiak 100
Page 4-103
190-02102-00 Rev.4
Table 4-24. PFT Faults
Monitor PFT Step
Notes
INTERNAL COMM
TESTFAIL
This can sometimes be the result of a failure on the
other board. Check faults on the other processor.
CTL MOT PWR ON FAIL
Check unit power and AP Disconnect power.
MON SOL PWR ON FAIL
Check unit power and AP Disconnect power.
HALL 1 FAIL
Check unit power and AP Disconnect power.
HALL 2 FAIL
Check unit power and AP Disconnect power.
HALL 3 FAIL
Check unit power and AP Disconnect power.
HALL 4 FAIL
Check unit power and AP Disconnect power.
HALL 5 FAIL
Check unit power and AP Disconnect power.
HALL 6 FAIL
Check unit power and AP Disconnect power.
CURR OFFSET FAIL
Check unit power and AP Disconnect power.
SVO TYPE FAIL
Check unit power and AP Disconnect power.
CERT DATA UNINSTALLED
Upload the certification gain file to the Monitor Board.
STRAP MODE MISMATCH
Check the connector strap inputs to the unit.
Table 4-25. Normal Mode Faults
Monitor Fault
Notes
GIA DIS FAULT
Check the AP Disconnect power to the unit.
HOST DATA DIF
Check the AHRS wiring to the system.
HOST DATA INV
Check the AHRS wiring to the system.
SVO PWER INV
Check unit power and AP Disconnect power.
STRP CODE CHNG
Check the connector strap inputs to the unit.
MET STUCK SWTCH
Check the MET switch inputs into the system.
MET STATUS DIF
Check the MET switch inputs into the system.
Uncontrolled if Printed