______________________________________________________________________________
____________________________________________________________________________
Page 8-8
LMM for the Kodiak 100
190-02102-00 Rev.4
TEST SPEED FAIL
Servo has not
responded to the test ini-
tialization command.
• Repeat test again.
• If message does not clear,
troubleshoot the servo
and it's wiring for the
source of the failure.
• If message does not clear,
troubleshoot the servo
and it's wiring for the
source of the failure.
SERVO TEST TIMED OUT Servo not responding for
over 60 seconds during
testing.
• Repeat test again.
SERVO DATA TIMED OUT The servo has failed to
transmit load cell sensor
status.
• Repeat test again.
• If message does not clear,
troubleshoot the servo
and it's wiring for the
source of the failure.
• If message does not clear,
troubleshoot the servo
and it's wiring for the
source of the failure.
LOAD CELL INVALID
A special test monitor
has detected an
inequality between
motor torque and load
cell torque greater than
the specified threshold.
An out-of-calibration
load cell may be the
cause.
• Replace servo motor and
repeat test.
AIRBORNE STATUS
The G1000 NXi has
detected airborne status,
(determined by true air-
speed) and has can-
celed the test.
• Verify the ADC is online.
• Check pitot/static system
is free of obstructions and
plumbing kink.
• Repeat test.
Table 8-1. (Continued)Troubleshooting Table
Message Prompt
Probable Cause
Action
Uncontrolled if Printed
Summary of Contents for Cessna Caravan G1000
Page 2: ...BLANK PAGE Uncontrolled if Printed...
Page 288: ...Uncontrolled if Printed...