______________________________________________________________________________
____________________________________________________________________________
LMM for the Kodiak 100
Page 3-19
190-02102-00 Rev.4
3.6 Loading Optional Equipment Software and Configuration
After baseline software and configuration have been loaded per
, the software
and configuration for optional equipment installed in the system can be loaded. To load
optional equipment software and configuration:
NOTE
If the configuration for an optional system is inadvertently loaded for a sys-
tem that is not installed, the basic Kodiak 100 Baseline Loads must be
reloaded. Following this, the configuration for the optional systems must be
repeated.
1. Insert the correct G1000 NXi Kodiak 100 Loader Card into the PFD1 top card
slot, if it is not already in the PFD.
2. Start both the PFDs and the MFD in configuration mode.
3. On PFD1, go to the System Upload page using the FMS knob.
4. Activate the cursor and use the small FMS knob to highlight Kodiak 100 Baseline
Loads in the GROUP field. Press the ENT key.
5. Once any of the Kodiak Options are selected and the cursor moves to the ITEM
field, turn the small FMS knob to generate a pick list. Move the cursor to highlight
any desired Option. Press ENT.
6. In the PRODUCT window, make sure that LRU VERS and CARD VERS are
listed. Make sure the Configuration box is checked.
7. Press the LOAD softkey.
8. If another option is to be loaded, use the large FMS knob to move the cursor back
up to the ITEM field. Turn the small FMS knob to again generate the pick list, then
move the cursor to highlight the next desired option available in the pick list.
Press ENT, then press the LOAD softkey.
9. Make sure the SUMMARY field lists the configuration upload as complete and
PASS is displayed next to the configuration check box.
10. Repeat Step 8 through steps 8 and 9 until all desired available options have been
loaded.
3.7 Loading Optional Features That Use Enablement Cards
The G1000 NXi system includes optional features that require use of enablement cards
for activation. Follow the procedure in this section to enable any of these features:
• Part Number 010-00330-5A, Enhanced AFCS
• Part Number 010-00330-50, Chartview Only
• Part Number 010-00330-51, TAWS-B
Uncontrolled if Printed
Summary of Contents for Cessna Caravan G1000
Page 2: ...BLANK PAGE Uncontrolled if Printed...
Page 288: ...Uncontrolled if Printed...