______________________________________________________________________________
____________________________________________________________________________
Page 3-24
LMM for the Kodiak 100
190-02102-00 Rev.4
Figure 3-20. Unsynced Summary
The listed LRUs would be the ones to check for the problems mentioned in the
troubleshooting section. The crossfill will still be ongoing even after the user cancels,
though it will no longer be monitored.
Figure 3-21. No Longer Waiting for Crossfill
Even though 'timeout' has occurred, crossfill still proceeds normally, and if the Crossfill
Monitor detects the network has synced all of the 'config' tags, it will still show a
completion message, even after timeout. This message will only be displayed if the user
has not yet canceled. Crossfill will still be ongoing even after the user cancels, though it
will no longer be monitored.
Figure 3-22. Crossfill completes after Timeout
NOTE
If the timeout has elapsed, an error has occurred and crossfill is not going
to finish. The technician should cancel, view the unsynced LRUs, and
proceed with troubleshooting, unless the decision is made to let it run as
part of troubleshooting.
Uncontrolled if Printed