Page 4-12
LMM for the Kodiak 100
190-02102-00 Rev.4
AHRS1 SRVC
The AHRS1 magnetic-field model
is out of date.
• GRS 79
AHRS1 TAS
AHRS1 is not receiving valid true
airspeed.
• GRS 79
CNFG MODULE
The PFD (master) configuration
module is inoperative.
• GDU 1050
• Master Config
Module
COM1 INOP - CAL
The COM Calibration needs to be
checked.
• GIA 64W
COM1 CONFIG
A COM1 configuration error.
• GIA 64W
• Master Config
Module
COM1 INOP - CRNT
GIA COM current.
• Aircraft supply
voltage to the
GIA 64W
• Wiring
COM1 INOP - INTRL
A GIA internal fault.
• GIA 64W
COM1 MANIFEST
COM1 software mismatch.
• GIA 64W
COM1 PTT
The COM1 push-to-talk (PTT) key
line is stuck in the enabled state.
• GIA 64W
• GMA 1360D
COM1 REDUCED TX
POWER
Reduced COM transmit power.
• GIA 64W
COM1 RMT XFR
The COM1 remote transfer key
line is stuck in the enabled state.
• GIA 64W
COM1 SERVICE
A fault has been detected in the
COM subsystem of GIA1.
• GIA 64W
COM1 INOP - SERL
A COM Serial Communication
fault.
• GIA 64W
COM1 INOP - SYNTH
A COM Synthesizer Lock Fault.
• GIA 64W
COM1 TEMP
COM1 has exceeded its operating
temperature range.
• GIA 64W
COM2 INOP - CAL
The COM Calibration needs to be
checked.
• GIA 64W
Table 4-1. Troubleshooting System Messages (Continued)
System Message
Description
Possibly Faulty
LRU / Subsystem
Uncontrolled if Printed