______________________________________________________________________________
____________________________________________________________________________
LMM for the Kodiak 100
Page 4-13
190-02102-00 Rev.4
COM2 CONFIG
COM2 configuration error.
• GIA 64W
• Master Config
Module
COM2 INOP - CRNT
GIA COM current.
• Aircraft supply
voltage to the
GIA 64W
• Wiring
COM2 INOP - INTRL
A GIA internal fault.
• GIA 64W
COM2 MANIFEST
COM2 software mismatch.
• GIA 64W
COM2 PTT
The COM2 push-to-talk (PTT) key
line is stuck in the enabled state.
• GIA 64W
• GMA 1360D
COM2 REDUCED TX
POWER
Reduced COM transmit power.
• GIA 64W
COM2 RMT XFR
The COM2 remote transfer key
line is stuck in the enabled state.
• GIA 64W
COM2 SERVICE
A fault has been detected in the
COM subsystem of GIA2.
• GIA 64W
COM2 INOP - SERL
A COM Serial Communication
fault.
• GIA 64W
COM2 INOP - SYNTH
A COM Synthesizer Lock Fault.
• GIA 64W
COM2 TEMP
COM2 has exceeded its operating
temperature range.
• GIA 64W
DATA LOST
The pilot profile data was lost.
• GDU 1050
DB MISMATCH
Navigation database mismatch.
Crosstalk is off.
• GDU 1050
DB MISMATCH
Obstacle database mismatch.
• GDU 1050
DATABASES
MISMATCHED
Databases mismatch.
• GDU 1050
DB MISMATCH
Terrain database mismatch.
• GDU 1050
FAILED PATH
A data path connected to a GDU
and/or GIA has failed.
• GDU 1050
• GIA 64W
Table 4-1. Troubleshooting System Messages (Continued)
System Message
Description
Possibly Faulty
LRU / Subsystem
Uncontrolled if Printed
Summary of Contents for Cessna Caravan G1000
Page 2: ...BLANK PAGE Uncontrolled if Printed...
Page 288: ...Uncontrolled if Printed...