______________________________________________________________________________
____________________________________________________________________________
Page 4-14
LMM for the Kodiak 100
190-02102-00 Rev.4
G/S1 FAIL
A failure has been detected in the
Glideslope subsystem of GIA1.
• GIA 64W
G/S1 SERVICE
A failure has been detected in the
Glideslope subsystem of GIA1.
The receiver may still be available.
• GIA 64W
G/S2 FAIL
A failure has been detected in the
Glideslope subsystem of GIA2.
• GIA 64W
G/S2 SERVICE
A failure has been detected in the
Glideslope subsystem of GIA2.
The receiver may still be available.
• GIA 64W
GDC1 MANIFEST
GDC1 software mismatch.
Communication halted.
• GDC 72
GEA1 CM INOP-COMM
GEA1 Configuration Module
connection.
• GEA 71B
• Master Config
Module
GEA1 CONFIG
GEA1 configuration error.
• GEA 71B
• Master Config
Module
GEA1 INOP-CAL
GEA1 rigging.
• GEA 71B
GEA1 INOP-CNFG
GEA1 software and configuration.
• GEA 71B
GEA1 INOP-INTRL
GEA1 internal fault.
• GEA 71B
GEA1 INOP-SENS
GEA1 configuration.
• GEA 71B
GEA1 CM INOP-TEMP
GEA1 cooling.
• Cooling
• GEA 71B
GEA1 MANIFEST
GEA1 software mismatch.
• GEA 71B
GIA1 CONFIG
GIA1 configuration error.
• GIA 64W
GIA1 CONFIG
GIA1 audio configuration error.
• GIA 64W
GIA1 COOLING
The GIA1 operating temperature
is too low to operate properly.
• GIA 64W
GIA1 COOLING
GIA1 has exceeded its operating
temperature range.
• GIA 64W
Table 4-1. Troubleshooting System Messages (Continued)
System Message
Description
Possibly Faulty
LRU / Subsystem