Page 5-58
Cirrus Perspective™ Line Maintenance Manual
Rev. E
190-00920-00
Miscellaneous
Alerts
(continued)
Message
Cause
Solutions
MFD
CONFIG
–
MFD
configuration
error.
Config
service
req’d.
The
system
has
detected
a
MFD
configuration
mismatch.
•
Reload
MFD
configuration
files
from
SD
Loader
Card.
•
Reload
system
configuration
files
by
pressing
the
UPDT
CFG
softkey
on
the
Configuration
Upload
Page
in
the
System
Page
Group
to
load
configuration
files
into
the
configuration
module.
−
If
message
persists,
check
config
module
wiring
for
faults
and
replace
if
necessary.
−
If
problem
persists,
replace
the
MFD.
PFD
VOLTAGE
–
PFD
has
low
voltage.
Reduce
power
usage.
PFD
is
not
receiving
sufficient
voltage.
•
Check
input
voltage
to
PFD.
−
If
input
voltage
is
ok,
replace
PFD.
MFD1
VOLTAGE
–
MFD1
has
low
voltage.
Reduce
power
usage.
The
MFD
is
not
receiving
sufficient
voltage.
•
Check
input
voltage
to
the
MFD.
−
If
input
voltage
is
ok,
replace
the
MFD.