____________________________________________________________________
Page 5-62
Cirrus Perspective™ Line Maintenance Manual
Rev. E
190-00920-00
5.7.2
GMA
347
Alerts
Message
Cause
Solutions
MANIFEST
–
GMA1
software
mismatch.
Communication
Halted.
The
system
has
detected
an
incorrect
software
version
loaded
in
GMA
347.
•
Load
correct
software
version.
GMA1
SERVICE
–
GMA1
needs
service.
Return
unit
for
repair.
The
system
has
determined
GMA
347
needs
service.
•
Replace
the
GMA
347.
GMA1
FAIL
–
GMA
1
is
inoperative.
The
system
has
detected
a
failure
in
GMA
347.
•
Make
sure
the
347
is
receiving
power.
•
Make
sure
both
GIAs
are
receiving
power.
•
Make
sure
all
GDUs
are
receiving
power.
•
Make
sure
the
347/GIA
RS
‐
232
data
lines
are
working
properly.
•
Make
sure
the
GIA/GDU
Ethernet
data
lines
are
working
properly.
•
Replace
347.
GMA1
CONFIG
–
GMA1
configuration
error.
Config
service
req’d.
The
system
has
detected
a
GMA
347
configuration
mismatch.
•
Load
347
configuration
files
(see
Section
7).
•
Replace
GMA
347.
•
If
problem
persists,
check
config
module
wiring
for
faults
and
replace
if
necessary.
Summary of Contents for Cirrus Perspective SR20