Page 5-82
Cirrus Perspective™ Line Maintenance Manual
Rev. E
190-00920-00
5.12
GEA
71
Related
Alerts
and
Problems
Message
Cause
Solutions
GEA1
CONFIG
–
GEA1
configuration
error.
Config
service
req’d.
The
system
has
detected
a
GEA
71
configuration
mismatch.
•
See
Section
7
for
instructions
on
configuration.
•
If
problem
persists,
check
config
module
harness
for
faults
and
replace
if
necessary.
MANIFEST
–
GEA1
software
mismatch.
Communication
Halted.
The
system
has
detected
an
incorrect
software
version
loaded
in
GEA
71.
•
Load
correct
software
version.
Discharged
standby
battery
Indication.
ALT1,
ALT2,
and
BAT1
circuits
needs
to
be
recalibrated
•
Refer
to
Section
5.10.1
for
the
High
Side
Current
Monitor
calibration
Procedure.