__________________________________________________________________
Page 7-16
Cirrus Perspective™ Line Maintenance Manual
Rev. E
190-00920-00
8.
Set
the
WX
‐
500
to
STRIKE
mode,
100
NM
range
(or
next
highest
available
range).
9.
Select
the
‘Continuous
Out’
mode
from
the
WX
‐
PA
menu
then
press
MENU/ENTER.
10.
Select
the
bottom
mount
antenna
configuration
on
the
WX
‐
PA
keyboard
(“A”
key).
11.
Select
a
cardinal
bearing
and
a
range
of
120
NM.
12.
Use
the
F1
and
F2
keys
to
adjust
range
and
F3
and
F4
keys
to
adjust
heading.
Press
MENU/ENTER
to
start
the
test.
13.
Observe
the
MFD
to
ensure
the
proper
positioning
of
the
strikes,
based
on
range
and
azimuth
settings
on
the
WX
‐
PA.
Change
the
cardinal
bearings
and
verify
correct
test
strikes.
Verify
the
strikes
are
within
10
degrees
of
the
selected
azimuth
and
plot
at
60
NM
(½
of
120
NM).
14.
Verify
after
20
seconds
of
operation
that
the
strike
counter
reads
580
±
40.
15.
After
testing
for
all
indicated
ranges
and
bearings,
press
second,
then
MENU/ENTER
to
return
to
the
main
menu.
16.
Select
Circular
Pattern
mode
from
the
WX
‐
PA
mode
menu
then
press
MENU/ENTER.
17.
Select
the
bottom
mount
antenna
configuration
on
the
WX
‐
PA
keyboard
(“A”
key).
Use
the
F1
and
F2
keys
to
select
the
120
NM
range
and
press
MENU/ENTER
to
start
the
test.
Make
sure
the
WX
‐
500
plots
discharge
points
at
approximately
60
NM.
18.
Observe
the
MFD
to
ensure
the
proper
positioning
of
the
test
strikes.
Verify
the
strikes
are
within
10
degrees
of
the
30
degree
azimuth
increment
and
within
12
NM
of
60
NM.
19.
When
complete,
set
WX
‐
PA
for
55
NM,
set
the
MFD
for
50
NM
(or
the
next
highest
available
range)
and
repeat
the
test.
20.
On
the
MFD,
verify
the
sensor
plots
points
just
outside
of
25
NM
and
the
strikes
are
within
10
degrees
of
the
30
degree
azimuth
and
within
5
NM
of
27.5
NM.
21.
Repeat
the
above
setting
on
the
MFD
for
25
NM
(or
the
next
highest
available
range)
and
the
WX
‐
PA
for
15
NM.
22.
On
the
MFD,
verify
the
positioning
of
test
strikes.
Make
sure
they
are
within
10
degrees
of
azimuth
and
within
2
NM
of
7.5
NM.
23.
Restart
in
configuration
mode
by
opening
the
PFD
and
MFD
circuit
breakers.
Press
and
hold
the
ENT
keys
on
the
PFD
and
MFD
and
close
the
PFD
and
MFD
circuit
breakers
to
restore
power.
24.
Select
the
‘OTHER’
page
group
on
the
MFD.
The
STORMSCOPE
page
is
shown
by
default.
Summary of Contents for Cirrus Perspective SR20