__________________________________________________________________
Page 8-6
Cirrus Perspective™ Line Maintenance Manual
Rev. E
190-00920-00
12.
Activate
the
cursor
and
select
GIA2
in
the
SELECT
UNIT
field,
then
press
the
ENT
key.
13.
Repeat
Steps
9
and
10.
14.
On
the
PFD,
go
to
the
CAN/RS
‐
485
CONFIGURATION
page
in
the
GIA
Page
Group.
15.
Verify
that
GIA1
is
selected
in
the
SELECT
UNIT
field.
16.
Observe
the
data
indicators
for
all
configured
RS
‐
485
channels.
17.
Make
sure
all
DATA
indicators
for
configured
channels
are
GREEN,
indicating
the
channels
are
receiving
data
as
shown
in
Figure
8
‐
3
and
8
‐
4.
Figure
8
‐
3.
CAN/RS
‐
485
Config
Page
(GIA1
Data
Indicators)
18.
Activate
the
cursor
and
select
GIA2
in
the
SELECT
UNIT
field
then
press
the
ENT
key.
19.
Repeat
Steps
15
and
16.
Summary of Contents for Cirrus Perspective SR20