78
Pin
Pin
Name
I/O
1
CONFIG
MODULE
GROUND
‐‐
2
DIGITAL
IN*
1
In
3
DIGITAL
IN*
2
In
4
SIGNAL
GROUND
‐‐
5
RS
‐
485
1
A
I/O
6
RS
‐
485
1
B
I/O
7
RS
‐
485
2
A
I/O
8
RS
‐
485
2
B
I/O
9
GEA
SYSTEM
ID
PROGRAM*
1
In
10
GEA
SYSTEM
ID
PROGRAM*
2
In
11
TRANSDUCER
POWER
OUT
LO
(GROUND)
‐‐
12
TRANSDUCER
POWER
OUT
LO
(GROUND)
‐‐
13
TRANSDUCER
POWER
OUT
LO
(GROUND)
‐‐
14
+10
VDC
TRANSDUCER
POWER
OUT
Out
15
+5
VDC
TRANSDUCER
POWER
OUT
Out
16
+12
VDC
TRANSDUCER
POWER
OUT
Out
17
ENGINE
TEMP
ANALOG
IN
6
HI
In
18
ENGINE
TEMP
ANALOG
IN
6
LO
In
19
SIGNAL
GROUND
‐‐
20
POWER
GROUND
‐‐
21
CONFIG
MODULE
POWER
OUT
Out
22
ANALOG
IN
1
HI
In
23
ANALOG
IN
1
LO
In
24
ANALOG
IN
2
HI
In
25
ANALOG
IN
2
LO
In
26
ENGINE
TEMP
ANALOG
IN
1
HI
In
27
ENGINE
TEMP
ANALOG
IN
1
LO
In
28
ENGINE
TEMP
ANALOG
IN
2
HI
In
29
ENGINE
TEMP
ANALOG
IN
2
LO
In
30
ENGINE
TEMP
ANALOG
IN
3
HI
In
31
ENGINE
TEMP
ANALOG
IN
3
LO
In
32
SIGNAL
GROUND
‐‐
33
ENGINE
TEMP
ANALOG
IN
4
HI
In
34
ENGINE
TEMP
ANALOG
IN
4
LO
In
35
AIRCRAFT
POWER
1
In
36
ENGINE
TEMP
ANALOG
IN
5
HI
In
37
AIRCRAFT
POWER
2
In
38
ENGINE
TEMP
ANALOG
IN
5
LO
In
Cirrus Perspective Line Maintenance Manual
Page A-19
190-00920-00
Rev.
D
Summary of Contents for Cirrus Perspective SR20
Page 2: ......