____________________________________________________________________
Cirrus Perspective™ Line Maintenance Manual
Page 5-25
190-00920-00
Rev.
E
GIA1
RS
‐
232
(continued)
Channel
LRU
Indicator
Status
CHNL
6
GRS
77
#1
GIA1/GRS
77
#1
data
path
is
functioning
correctly.
GIA1/GRS
77
#1
data
path
is
not
functioning
correctly.
•
Check
PFD
Alert
Window
for
GIA
or
GRS
configuration
or
software
error
messages.
Correct
any
errors
before
proceeding.
•
Make
sure
the
GRS77
#1
status
is
OK
using
the
AUX
‐
SYSTEM
STATUS
PAGE
on
the
MFD.
If
there
is
a
Red
‐
X,
troubleshoot
why
the
GRS
is
offline
before
proceeding.
•
Make
sure
the
GRS77
#1
connecter
is
secure
and
proper
wire
harness
strain
relief
is
provided.
•
Swap
GIA1
and
GIA2,
reconfigure
both
GIA’s
at
their
new
locations
to
see
if
the
problem
is
in
the
original
GIA1.
−
Replace
original
GIA1
if
box
turns
green
after
swapping
units.
•
Swap
GRS77
#1
and
GRS77
#2
(if
a
GRS77
#2
is
installed)
to
see
if
the
problem
is
in
the
original
GRS77
#1.
−
Replace
original
GRS77
#1
if
box
turns
green
after
swapping
units.
•
Check
the
GIA1/GRS
77
#1
interconnect
wiring
and
unit
connector
pins
for
faults.
•
Replace
GRS
77
#1.
GIA1/GRS
77
#1
data
path
functionality
is
unknown.
Reload
GIA1
configuration
files.