Cirrus Perspective™ Line Maintenance Manual
Page 5-43
190-00920-00
Rev.
E
CHNL
4
GFC
700
GIA1/GFC
700
data
path
is
functioning
correctly.
GIA1/GFC
700
data
path
is
not
functioning
correctly.
•
Check
PFD
Alert
Window
for
GIA,
GFC,
GTA
or
GSA
configuration
or
software
error
messages.
Correct
any
errors
before
proceeding.
•
Make
sure
all
GSA/GTA
servo
statuses
are
OK
using
the
AUX
‐
SYSTEM
STATUS
PAGE
on
the
MFD.
If
one
or
all
show
a
Red
‐
X,
troubleshoot
why
the
servos
are
offline
before
proceeding.
•
Swap
GIA1
and
GIA2.
Reconfigure
both
GIA’s
at
their
new
locations
to
see
if
the
problem
is
in
the
original
GIA1.
−
Replace
original
GIA1
if
box
turns
green
after
swapping
units.
•
Check
the
GIA1/GSA/GTA
interconnect
wiring
and
connector
pins
for
faults.
•
Proceed
to
the
Autopilot
Troubleshooting
section
for
further
assistance.
GIA1/GFC
700
data
path
functionality
is
unknown.
Reload
GIA1
and
GFC700
configuration
files.
Summary of Contents for Cirrus Perspective SR20