190-01700-00
Flight Stream 110/210 TSO Installation Manual
Rev. B
Page 3-4
NOTE
Each tapped hole on the shield block may accommodate only two ring terminals. It is
preferred that a maximum of two wires be terminated per Ring Terminal. Two wires per
ring terminal will necessitate the use of a ring terminal, #8, insulated, 14-16 AWG
(MS25036-153). If only a single wire is left, or if only a single wire is needed for this
connector a ring terminal, #8, insulated, 18-22 AWG (MS25036-149) can accommodate
this single wire. If more wires exist for the connector than two per ring terminal, it is
permissible to terminate three wires per ring terminal.
5. Terminate the ring terminals to the shield block by placing items on the pan head screw in the
following order: split washer, flat washer, first ring terminal, second ring terminal if needed,
before finally inserting the screw into the tapped holes on the shield block.
6. Wrap the cable bundle with silicone fusion tape (P/N 249-00114-00 or a similar version) at the
point where the backshell strain relief, and cast housing will contact the cable bundle.
7. Place the smooth side of the backshell strain relief across the cable bundle and secure using the
two screws.
WARNING
Placing the grooved side of the strain relief across the cable bundle may damage wires.
8. Attach the cover to the backshell using two screws.