Page 6-2
G1000 Nav III Line Maintenance Manual
Rev. L
190-00352-00
9. GDL
90
Refer to the GDL 90 Installation Manual (560-1049-02) for periodic maintenance information.
10. GDU
1040
For all units that comply with the mod status level listed in Table 6-1, maintenance of the GDU 1040 is
“on condition” only.
For all units that do
not
comply with the mod status level listed in Table 6-1, perform the power interrupt
annual inspection as described in Section 6.5.
Unit
Unit Part Number
Long Term
Power Interrupt
Category B (50 mS)*
Mod Status
011-00972-00 2
GDU 1040
011-00972-03 1
GDU 1044B
011-01274-00
1
*Per RTCA DO-160D Section 16
Table 6-1. Long Term Power Interrupt Category B (50 mS) Mod Status