Page B-4
G1000 Nav III Line Maintenance Manual
Rev.L
190-00352-00
B.1.2
Initial G1000 Configuration
Standard Configuration (GDU software version 6.01 and earlier)
When loading the standard (default) configuration for each airframe, the user should select the ‘FULL
CONFIGURATION’ item listed in the drop-down menu. Selecting the ‘FULL CONFIGURATION’ populates
the SECTION window with all of the individual configurable items. The user can then select each individual
LRU to install the appropriate base configuration settings.
1.
Go to the CONFIGURATION UPLOAD page using the FMS knob.
2.
Activate the cursor and highlight the appropriate file in the FILE field.
3.
Press the ENT key.
4.
Highlight ‘AIRFRAME’ in the SECTION field.
5.
Press the LOAD softkey.
6.
Select YES and press the ENT key to acknowledge the following prompt:
7.
Monitor the status of the upload. When the upload is finished, press the ENT key to acknowledge the
following confirmation: