Page 1-16
G1000 Nav III Line Maintenance Manual
Rev. L
190-00352-00
1.4.13
ACTV>SET Interface
The only time ACTV>SET should be used is when the master configuration module fails and must be replaced.
In this circumstance the ACTV>SET softkey may be used to reload correct configuration settings from previously
installed LRUs. Should a LRU be replaced along with the master configuration module, the LRU needs to be
reconfigured using the G1000 SW Loader Card.
WARNING
The ACTV>SET softkey must be used with caution! If an improperly configured unit is
installed, this softkey causes the wrong configuration to replace the correct aircraft configuration!
=
=
Master Configuration Module
LRU Memory
Master Configuration Module
LRU Memory
Master Configuration Module
LRU Memory
=
Master Configuration Module
LRU Memory
=
Configuration Mismatch
SET>ACTV Softkey
Configuration Correct
Figure 1-11. SET/ACTV Feature
In most cases, when a setting is changed, the newer setting will automatically be transferred to the appropriate
LRU. The technician receives on-screen confirmation that the configuration is successful, as depicted in
Figure 1-12. Likewise, if a configuration error is detected, it too is shown in similar fashion.
Figure 1-12. Configuration Status
Summary of Contents for G1000 NAV III
Page 1: ...190 00352 00 March 2008 Rev L G1000 NAV III LINE MAINTENANCE MANUAL ...
Page 28: ...Page 1 18 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...
Page 120: ...Page 2 92 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...
Page 184: ...Page 6 6 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...
Page 248: ...Page B 34 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...