2.1.5.4 GIA CAN / RS-485 CONFIGURATION Page
GIA1 RS-485
Channel LRU Indicator
Status
GIA1/GEA data path is functioning correctly.
GIA1/GEA data path is not functioning correctly.
•
Reconfigure GIA1.
•
Reconfigure GEA.
•
Check the GIA1/GEA interconnect for wiring faults.
•
Swap the GIA’s to confirm if the problem is in the original
GIA.
o
Replace original GIA if box turns green after
swapping units.
o
Replace GEA if problem persists.
CHNL 1
GEA1
GIA1/GEA data path functionality is unknown. Reload GIA1
configuration file.
GIA1/GFC 700 data path is functioning correctly.
GIA1/GFC 700 data path is not functioning correctly.
•
Reconfigure GIA1.
•
Reload GFC 700 Installation configuration files (if equipped).
•
Check the GIA1/GSA servo interconnects for wiring faults.
•
Swap the GIA’s to confirm if the problem is in the original
GIA.
o
Replace original GIA if box turns green after
swapping units.
o
Troubleshoot GSA servos to determine which one is
causing the problem (ref section 2.10).
CHNL 4
GFC 700
GIA1/GFC 700 data path functionality is unknown. Reload GFC 700
Installation configuration files (if equipped).
Summary of Contents for G1000 NAV III
Page 1: ...190 00352 00 March 2008 Rev L G1000 NAV III LINE MAINTENANCE MANUAL ...
Page 28: ...Page 1 18 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...
Page 120: ...Page 2 92 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...
Page 184: ...Page 6 6 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...
Page 248: ...Page B 34 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...