Page 2-32
G1000 Nav III Line Maintenance Manual
Rev. L
190-00352-00
Message Cause
Solutions
CNFG MODULE – PFD1
configuration module is
inoperative.
The PFD master
configuration module has
failed.
•
Check master configuration module
connector and wiring for damage inside
the GDU connector backshell.
o
Replace master configuration
module wiring and pins.
o
If problem persists, replace master
configuration module.
NOTE
New Terrain/Obstacle cards, Jeppesen
Aviation Database and other optional
features (i.e. TAWS unlock card) will need
to be replaced if the master configuration
module is changed. The G1000 System ID
number will change to a new number when
installing a new master config module. The
old Terrain and other cards will no longer
work as they will remain locked to the old
System ID number.
2.2.4
GDU Cooling Alerts
Message Cause
Solutions
MFD1 COOLING – has poor
cooling. Reducing power usage.
MFD1 has exceeded it’s
operating temperature
range.
•
Check cooling fan and wiring for proper
operation (if applicable).
o
If problem persists, replace the
MFD.
o
If problem continues contact
Garmin Aviation Product Support
for assistance.
PFD1 COOLING – has poor
cooling. Reducing power usage.
The PFD has exceeded it’s
operating temperature
range.
•
Check cooling fan and wiring for proper
operation (if applicable).
o
If problem persists, replace the
PFD.
o
If problem continues contact
Garmin Aviation Product Support
for assistance.
Summary of Contents for G1000 NAV III
Page 1: ...190 00352 00 March 2008 Rev L G1000 NAV III LINE MAINTENANCE MANUAL ...
Page 28: ...Page 1 18 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...
Page 120: ...Page 2 92 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...
Page 184: ...Page 6 6 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...
Page 248: ...Page B 34 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...