G1000 Nav III Line Maintenance Manual
Page 2-45
190-00352-00
Rev.
L
2.4.1.3
GIA I/O CONFIGURATION Page
Figure 2-16. GIA I/O CONFIGURATION Page
Discrete and analog input/output channels for GIA 1 and GIA 2 are shown on this page. All settings are pre-
established for a particular installation and are loaded from the G1000 Loader Card and should not be changed.
The ‘GIA1’ and ‘GIA2’ configuration files contain the settings shown on this page.
SELECT GIA UNIT
This window shows the currently selected GIA 63/GIA 63W unit.
SELECT INPUT/OUTPUT
This window shows input/output type that is displayed for the currently selected GIA. Options include:
Discrete In
Discrete Out
Analog In
Analog Out
CONFIGURATION
This window shows active I/O configuration settings for the currently selected GIA and input/output type.
A
green box indicates an input is active, a black/red box indicates an input is not active or not is use.
SOFTKEYS
The following softkeys appear at this page:
•
SET>ACTV: See Section 1.4.12 for description.
•
ACTV>SET: See Section 1.4.12 for description.