G1000 Supplemental Maintenance Manual
Page 5-18
Textron Nav III Series
Revision 3
190-02128-04
Failure Message
Cause
Solution
MFD1 CONFIG
– MFD1
configuration error. Config service
req’d.
A configuration mismatch has
occurred between the display and
the Master Configuration Module.
•
Reload the display configuration
files from SD Loader Card.
•
Reload system configuration files
by pressing the UPDT CFG
softkey on the Configuration
Upload Page in the PFD System
Page Group to load configuration
files into the configuration module.
✓
If message persists, check
PFD config module wiring for
faults and replace if necessary.
✓
If issue continues, replace
PFD master configuration
module.
✓
If problem persists, replace the
display.
NOTE
New Terrain/Obstacle databases,
Jeppesen Aviation Database and other
optional features (i.e. TAWS unlock
card) will need to be replaced if the
master configuration module is
changed. The G1000 System ID
number will change to a new number
when installing a new master config
module. The old Terrain and other
databases will no longer work as they
will remain locked to the old System ID
number.
PFD 1 CONFIG
– PFD 1
configuration error. Config service
req’d.
Summary of Contents for G1000 NXi