Figure 6-9 – Pressure Sensor, Coupling Mount Type
6.6.1.2 Oil Temperature
When installing the oil temperature sensor, the unbroken side of the crush washer must face the sensor
flange. The sensor is torqued finger tight plus one-half turn and safety wired in accordance with practices
defined in Section 7,
Safetying,
of Chapter 7,
Aircraft Hardware, Control Cables and Turnbuckles,
of advisory
circular AC 43.13-1B,
Aircraft Inspection and Repair.
6.6.1.3 Carburetor Air Temperature
The sensor location will vary for different carburetors. Reinstall the carburetor temperature sensor as
described in Figure 6-10.
CAUTION
Fuel and air passages must remain free of contaminants during work near and around the
carburetor.