190-01115-01
G3X/G3X Touch Installation Manual - LRU Pinouts
Rev. AC
Page 25-16
25.3.4
Serial Data
25.3.4.1
RS-232
3 Channels of RS-232 I/O data.
25.3.4.2
CAN Bus
This data bus conforms to the BOSCH standard for Controller Area Network 2.0-B. This bus complies
with ISO 11898. CAN BUS TERMINATION should be connected to CAN BUS LO for the GDU that is
located at the end of the bus (farthest from the GSU 73), see
for details.
25.3.4.3
Configuration Module
Connect the configuration module to the PFD1 unit; do not connect a config module to PFD2 or the MFD.
Pin Name
Connector
Pin
I/O
RS-232 IN 1
J3701
47
In
RS-232 OUT 1
J3701
48
Out
RS-232 IN 2
J3701
14
In
RS-232 OUT 2
J3701
30
Out
RS-232 IN 3
J3701
29
In
RS-232 OUT 3
J3701
13
Out
Pin Name
Connector
Pin
I/O
CAN BUS HI
J3701
46
I/O
CAN BUS LO
J3701
45
I/O
CAN BUS TERMINATION
J3701
28
--
Pin Name
Wire Color
Connector
Pin
I/O
CONFIG MODULE CLOCK
WHITE (WHT)
J3701
33
I/O
CONFIG MODULE DATA
YELLOW (YEL)
J3701
50
I/O
CONFIG MODULE POWER OUT
RED (RED)
J3701
17
Out
CONFIG MODULE GROUND
BLACK (BLK)
J3701
49
--