190-01115-01 G3X/G3X Touch Installation Manual - GDU 37X Config and Post Install Checkout
Rev. AC
Page 33-36
7. Follow the on-screen instructions by slowly turning the aircraft to the right, the dots at the end of
the text will be removed as the aircraft rotates 30 degrees. When all of the dots have been
removed, and the text changes to ‘Hold Position’, stop turning the aircraft, and wait for further
instructions.
8. Continue following the on-screen instructions until the calibration is completed. The calibration
will go through 12 cycles of holding, then turning to the right before completing a full circle.
9. When the calibration is finished, ensure that a Calibration Status of “Success” is displayed, press
the Done softkey to return to the MAG Configuration Page.
NOTE
If more than one magnetometer is installed, it is recommended to perform the Magnetic
Calibration Procedure for both magnetometers consecutively, one procedure immediately
followed by the next. This is especially important if something about the airplane has
been changed that required a repeat of the Magnetic Calibration Procedure.