190-01115-01
G3X/G3X Touch Install Manual - GDU 4XX Config and Post Install Checkout
Rev. AC
Page 34-40
Caution Alert AOA Calibration
This procedure sets the AOA value for the bottom of the yellow "chevron" section of the AOA gauge
(Figure 34-11), which is also the AOA value at which the audible stall warning sound will begin to
intermittently play. Perform this calibration while flying the aircraft at an AOA below the aircraft's stall
AOA (1.1 x stall speed is suggested).
Figure 34-11 Caution Alert AOA
1.
Use the Touch Panel or a Move Selector Knob to select the Caution Alert AOA Calibration field,
then press the Calibrate button.
2. Follow the onscreen instructions, then press the Start button to begin the calibration.
3. Press the Calibrate button when in compliance with the onscreen instructions.
Caution Alert
AOA (Audio Tone
Sounds Inermittently)