190-01115-01
G3X/G3X Touch Installation Manual - Airframe Specific Installation Guidance
Rev. AC
Page A-13
14. Apply epoxy resin to the flat side of the nut plate washers, see Figure A-17.
Figure A-17 Nut Plate Washers
15. Apply a small amount of release agent on the
stainless steel
MS51958 screw threads.
16. Attach GMU assembly to wing rib as shown in Figure A-18.
Figure A-18 Magnetometer Assembly attached to Wing Rib
NOTE
Stainless steel hardware (nut plates and screws) must be used to attach the GMU 22
bracket to the wing.
NOTE
The wing tip should also be attached with stainless steel hardware (nut plates and screws).
NOTE
Never use a magnetic screwdriver to remove or install wingtip hardware.