190-01115-01
G3X/G3X Touch Installation Manual - Connector Installation Instructions
Rev. AC
Page 24-5
NOTE
For the following steps please refer to Figure 24-4 &
1. Strip back approximately 0.17 inches of insulation from each wire of the four conductor wire
harness (item 3, Figure 24-4) and crimp either a pin (item 4, Figure 24-4) or a socket (item 9,
Figure 24-4) to each conductor. It is the responsibility of the installer to determine the proper
length of insulation to be removed. Wire must be visible in the inspection hole after crimping and
the insulation must be 1/64 – 1/32 inches from the end of the contact as shown in Figure 24-4.
Figure 24-4 Insulation/Contact Clearance
NOTE
Refer to
for all item numbers in the following steps 2-6.
2. Insert newly crimped pins (or sockets) and wires (items 3 and 4) into the appropriate connector
housing (item 5) location as specified by the installation specific wiring diagram.
3. Attach the module (item 1) to backshell (item 6) using screw (item 10).
4. Plug the four conductor wire harness (item 3) into the connector on the module (item 1).
5. Orient the connector housing (item 5) so that the inserted four conductor wire harness (item 3) is on the
same side of the backshell (item 6) as the module (item 1).
6. Attach cover (item 7) to backshell (item 6) using screws (item 8).
4 or 9
1