190-01115-01
G3X/G3X Touch Installation Manual - Jabiru Sensor Wiring Examples
Rev. AC
Page 32-1
32 JABIRU SENSOR WIRING EXAMPLES
32.1 Notes for Section 32 Drawings
Figure 32-1 Notes for Jabiru Sensor Drawings (for all Section 32 drawings)
SHIELD TERMINATED TO GROUND
SHIELD TERMINATED TO GROUND
TWISTED SHIELDED 3 CONDUCTOR
TWISTED SHIELDED 3 CONDUCTOR
SHIELD FLOATS
SHIELD FLOATS
TWISTED SHIELDED 3 CONDUCTOR
TWISTED SHIELDED 3 CONDUCTOR
4. SYMBOL DESIGNATIONS
4. SYMBOL DESIGNATIONS
TWISTED SHIELDED PAIR
TWISTED SHIELDED PAIR
SHIELD TERMINATED TO GROUND
SHIELD TERMINATED TO GROUND
SHIELD FLOATS
SHIELD FLOATS
TWISTED SHIELDED PAIR
TWISTED SHIELDED PAIR
TWISTED SHIELDED SINGLE CONDUCTOR
TWISTED SHIELDED SINGLE CONDUCTOR
SHIELD TERMINATED TO GROUND
SHIELD TERMINATED TO GROUND
SHIELD FLOATS
SHIELD FLOATS
TWISTED SHIELDED SINGLE CONDUCTOR
TWISTED SHIELDED SINGLE CONDUCTOR
1. UNLESS OTHERWISE NOTED, ALL STRANDED WIRE MUST CONFORM TO MIL-W-22759/16 OR EQUIVALENT
1. UNLESS OTHERWISE NOTED, ALL STRANDED WIRE MUST CONFORM TO MIL-W-22759/16 OR EQUIVALENT
2. UNLESS OTHERWISE NOTED, ALL SHIELDED WIRE MUST CONFORM TO MIL-C-27500 OR EQUIVALENT
2. UNLESS OTHERWISE NOTED, ALL SHIELDED WIRE MUST CONFORM TO MIL-C-27500 OR EQUIVALENT
3. UNLESS OTHERWISE NOTED, ALL WIRES ARE 24 GAUGE MINIMUM.
3. UNLESS OTHERWISE NOTED, ALL WIRES ARE 24 GAUGE MINIMUM.
5. UNLESS OTHERWISE NOTED, ALL SHIELD GROUNDS MUST BE MADE TO THE RESPECTIVE UNIT BACKSHELLS.
5. UNLESS OTHERWISE NOTED, ALL SHIELD GROUNDS MUST BE MADE TO THE RESPECTIVE UNIT BACKSHELLS.
ALL OTHER GROUNDS SHOULD BE TERMINATED TO AIRCRAFT GROUND AS CLOSE TO THE RESPECTIVE UNIT AS POSSIBLE.
ALL OTHER GROUNDS SHOULD BE TERMINATED TO AIRCRAFT GROUND AS CLOSE TO THE RESPECTIVE UNIT AS POSSIBLE.
NOTES:
NOTES:
WIRE SPLICE CONNECTION
WIRE SPLICE CONNECTION
COAXIAL CABLE
COAXIAL CABLE
SHIELD TERMINATED TO GROUND
SHIELD TERMINATED TO GROUND
TWISTED SHIELDED 4 CONDUCTOR
TWISTED SHIELDED 4 CONDUCTOR
SHIELD FLOATS
SHIELD FLOATS
TWISTED SHIELDED 4 CONDUCTOR
TWISTED SHIELDED 4 CONDUCTOR
N/C = NO CONNECTION
N/C = NO CONNECTION
7. RESERVED.
7. RESERVED.
S
GARMIN SHIELD BLOCK GROUND
GARMIN SHIELD BLOCK GROUND
6. PINOUT SHOWN FOR PACKARD CONNECTOR SUPPLIED WITH KAVLICO PRESSURE TRANSDUCERS. WIRE COLORS ARE SHOWN
6. PINOUT SHOWN FOR PACKARD CONNECTOR SUPPLIED WITH KAVLICO PRESSURE TRANSDUCERS. WIRE COLORS ARE SHOWN
8. IN THIS DOCUMENT, AN ASTERISK (*) IS USED FOR SIGNALS THAT ARE ACTIVE LOW (GROUND TO ACTIVATE). ON
8. IN THIS DOCUMENT, AN ASTERISK (*) IS USED FOR SIGNALS THAT ARE ACTIVE LOW (GROUND TO ACTIVATE). ON
INSTALLATION WIRING DIAGRAMS, THE MORE TRADITIONAL OVERLINE SYMBOLOGY IS USED.
INSTALLATION WIRING DIAGRAMS, THE MORE TRADITIONAL OVERLINE SYMBOLOGY IS USED.
AIRCRAFT GROUND
AIRCRAFT GROUND
9. OPTIONAL INSTALLATION.
9. OPTIONAL INSTALLATION.
11. THE RPM SIGNAL FOR THE JABIRU 3300 IS TYPICALLY OBTAINED BY TYING INTO ONE OF THE TWO WIRES RUNNING BETWEEN THE
11. THE RPM SIGNAL FOR THE JABIRU 3300 IS TYPICALLY OBTAINED BY TYING INTO ONE OF THE TWO WIRES RUNNING BETWEEN THE
10. IF INSTALLING UNGROUNDED THERMOCOUPLES, THE LO SIDE MUST BE TAKEN TO A GSU SIGNAL GROUND.
10. IF INSTALLING UNGROUNDED THERMOCOUPLES, THE LO SIDE MUST BE TAKEN TO A GSU SIGNAL GROUND.
12. IF MEASURING BATTERY CURRENT, PLACE THE SHUNT BETWEEN THE BATTERY POSITIVE TERMINAL AND THE BATTERY CONTACTOR.
12. IF MEASURING BATTERY CURRENT, PLACE THE SHUNT BETWEEN THE BATTERY POSITIVE TERMINAL AND THE BATTERY CONTACTOR.
IF MEASURING ALTERNATOR CURRENT, PLACE THE SHUNT BETWEEN THE ALTERNATOR B LEAD AND THE POWER DISTRIBUTION BUS.
IF MEASURING ALTERNATOR CURRENT, PLACE THE SHUNT BETWEEN THE ALTERNATOR B LEAD AND THE POWER DISTRIBUTION BUS.
ALTERNATOR AND THE ALTERNATOR REGULATOR. ONE OF THE TWO WHITE WIRES ON THE ALTERNATOR SIDE OR ONE OF THE
ALTERNATOR AND THE ALTERNATOR REGULATOR. ONE OF THE TWO WHITE WIRES ON THE ALTERNATOR SIDE OR ONE OF THE
TWO PALE BLUE WIRES ON THE REGULATOR SIDE CAN BE USED FOR THE SIGNAL.
TWO PALE BLUE WIRES ON THE REGULATOR SIDE CAN BE USED FOR THE SIGNAL.
FOR REFERENCE ONLY, ALWAYS CONFIRM CORRECT SENSOR CONNECTIONS USING SENSOR MANUFACTURER DOCUMENTATION
FOR REFERENCE ONLY, ALWAYS CONFIRM CORRECT SENSOR CONNECTIONS USING SENSOR MANUFACTURER DOCUMENTATION
BEFOR CONNECTING WIRES.
BEFOR CONNECTING WIRES.