190-01717-B1
G500/G600 TXi Part 23 AML STC Maintenance Manual
Rev. 1
Page 5-22
5.7.1
Removal
To remove the GEA 110, perform the following procedure:
1. Remove power to the GEA 110.
2. Disconnect the two electrical connectors.
3. If the unit is mounted on a tray as shown in Figure 5-12, pull out on the mounting knob and turn
counterclockwise to loosen it enough to rotate the arm down and away from the unit
4. If the unit is mounted to the airframe or back of the GDU using screws as shown in Figure 5-11,
loosen the four screws securing the unit to the airframe or GDU.
5.7.2
Re-Installation
To re-install the GEA 110, perform the removal procedures in reverse. If the unit is mounted to the
airframe or back of the GDU, torque the screws to the specification in Figure 5-11. For units that are
mounted in a mounting tray, tighten the mounting screw by hand until the unit is secure.
If the GEA 110 was replaced, the sensor configurations must be loaded to the new unit using the following
procedure:
1. Insert saved configuration SD card in the Top or Left SD card slot of any GDU 1060/700 directly
connected to the GEA 110.
2. Power on the GDU that is physically wired to the GEA 110 in configuration mode.
3. Press
SD Load.
4. Select the appropriate
Aircraft Configuration File
.
5. Select the current GDU as the
From SD
and
To GDU
.
6. Select the
EIS Sensor Configuration
check box.
7. Select
SD Load
.
5.7.3
Checkout
Perform the following checkout procedures:
1. Configuration Mode Ground Checks as described in Section 5.15.1. If the GEA 110 does not pass
the checks in this step, load the sensor configurations using the procedure in Section 5.7.2 above
and perform the checkout procedure again.
Perform the following checkout procedure only if the GEA was replaced or did not initially pass the
checkout procedure above:
1. EIS Ground Checks as described in Section 6.5 of the G500/G600 TXi Part 23 AML STC
Installation Manual (P/N: 190-01717-B3).