G900X/G950 Annunciations, Continued
Descriptive
Text
Brief Text
Annunciation
Type
Configuration
Category
Required
Triggers
(Reference
Table
14-1)
Annunciation
Logic (Refer to
Tables 14-4
through 14-7 for
airframe and
engine specific
configuration
details)
Active:
When
trigger 19 is
active.
Prop heat
system has
failed.
PROP HEAT
FAIL
Warning Common 19
Clear:
When
trigger 19 is
inactive.
Active:
When
trigger 3 is active.
Cabin
pressure
outside
normal
operating
limits.
CABIN
PRESSURE
Warning Common 3
Clear:
When
trigger 3 is
inactive.
Active:
When
trigger 36 is
active.
N/A
CHIP
DETECT
Caution Common 36
Clear:
When
trigger 36 is
inactive.
Active:
When
trigger 4 is active.
Deice system
is on.
DEICE ON
Safe
Annunciation
Common 4
Clear:
When
trigger 4 is
inactive.
Active:
When
trigger 1 is active.
Air conditioner
is on.
A/C ON
Safe
Annunciation
Common 1
Clear:
When
trigger 1 is
inactive.
Active:
When
trigger 5 is active.
Door seal
pump is on.
DOOR SEAL
Caution
Common
5
Clear:
When
trigger 5 is
inactive.